Radiat Prot Dosimetry ; 163(1): 118-24, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24707002

RESUMO

National guidance from the Institute of Physics and Engineering in Medicine (IPEM Report 91) currently recommends that the patient dose for a panoral X-ray unit is measured as dose area product (DAP) replacing dose width product described in earlier guidance. An investigation identifying different methods available to carry out this measurement has been undertaken and errors in the methodologies analysed. It has been shown that there may be up to a 30 % variation in DAP measurement between methods. This paper recommends that where possible a DAP meter is used to measure the dose-area product from a panoral X-ray unit to give a direct DAP measurement. However, by using a solid-state dose measurement and film/ruler to calculate DAP the authors have established a conversion factor of 1.4. It is strongly recommended that wherever a DAP value is quoted the methodology used to obtain that value is also reported.


Assuntos
Radiografia Panorâmica/normas , Humanos , Saúde Pública , Garantia da Qualidade dos Cuidados de Saúde , Doses de Radiação , Monitoramento de Radiação/instrumentação , Monitoramento de Radiação/métodos , Proteção Radiológica/legislação & jurisprudência , Proteção Radiológica/normas , Radiografia Panorâmica/efeitos adversos , Reino Unido
2.
Br J Radiol ; 74(883): 615-20, 2001 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11509397

RESUMO

The correct operation of a mammography system's automatic exposure control system (AEC) is essential if mammograms are to be produced with a suitable film exposure. A methodology has been developed that allows the performance of the AEC to be assessed quantitatively using clinical films. By digitizing mammograms, the mean optical density (OD) in the main breast region and in a region of interest corresponding to the position of the AEC detector are evaluated for each film, together with the area of the main breast. Using these data it is possible to determine the relationships between the mean OD, breast size and AEC detector position. The performance of the AEC on a GE Senographe 600 TS system was investigated. The study found that there is a tendency to underexpose smaller breasts, i.e. with an area less than approximately 4000 mm(2). This is equivalent to a compressed tissue width of approximately 60---80 mm. The difference in mean OD between the mammograms of small and large breasts was up to 0.7 OD. Provided the sensitive area of the AEC detector is known, this method of assessing AEC performance can be used with any mammography system.


Assuntos
Dosimetria Fotográfica , Mamografia/normas , Conversão Análogo-Digital , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Mamografia/instrumentação , Pessoa de Meia-Idade , Imagens de Fantasmas , Reprodutibilidade dos Testes